Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Maxillofacial Plastic and Reconstructive Surgery ; : 6-2021.
Article in English | WPRIM | ID: wpr-918492

ABSTRACT

Background@#Nicotine can have detrimental effects on dental implant osseointegration. This study aimed to evaluate the influence of systemic L-arginine supplement on the osseointegration of dental implants in nicotine consumer dogs. @*Methods@#Twelve 1-year Labrador Retriever dogs had their right and left third and fourth mandibular premolars removed, and the sockets were left to heal for 6 months. Dogs were randomly divided into three groups (n = 16): group 1—0.2 mg/kg nicotine was injected twice daily; group 2—0.2 mg/kg nicotine was injected twice daily in addition to 200 mg/kg L-arginine capsules taken orally; and group 3—placebo. Forty-eight dental implants were inserted into the healed sockets of the dog’s mandible and were assessed by implant stability quotient (ISQ) using resonance frequency analysis (RFA) during 4 weeks and insertion and removal torque value analysis. @*Results@#No implant failure occurred during the study period. The change in torque value between insertion and removal was similar in the placebo and nicotine+arginine consumer dogs (p = 0.276), which shows a positive effect of arginine supplementation in nicotine consumers. There was a significant difference in torque value change between nicotine+arginine vs. nicotine consumers (p = 0.049) and placebo vs. nicotine (p = 0.003). After 4 weeks, the placebo had the most significant improvement in torque value (47.0 ± 16.9), followed by nicotine+arginine (25.1 ± 37.8), and the worst torque value was for the nicotine group (− 5.7 ± 24.0) pound per inch. The results show that except in the first week, there are significant differences in ISQ between the groups in different periods. ISQ in all of the groups has reduced at first but then increased over time. At the time of implant placement, insertion torque was significantly higher in the nicotine consumer group than the nicotine+arginine consumer group and placebo group (p = 0.020). @*Conclusion@#Arginine supplementation promotes bone healing and implant primary stability by improving dental implant osseointegration biomechanical characteristics.

2.
Maxillofacial Plastic and Reconstructive Surgery ; : 11-2021.
Article in English | WPRIM | ID: wpr-918486

ABSTRACT

Background@#Orthognathic surgery is widely used in treating functional and skeletal problems. Any surgical procedure could cause side effects. @*Objectives@#This study aimed to evaluate the potential changes in orthognathic surgery on the hearing function of patients. @*Materials and methods@#Thirty-one orthognathic surgery candidates were recruited in this study. Patients underwent either single or double jaw surgery. Pure tone audiometry (PTA), tympanometry, and Eustachian Tube Dysfunction Test (ETFT) were performed postoperatively at 24 h, 6 weeks, and 6 months after surgery. Patients were tabulated based on the type of maxilla and mandibular surgical movements (vertical and horizontal). @*Results@#PTA evaluation, based on horizontal or vertical movements, did not show significant differences, although vertical movements resulted in less change in hearing threshold. In other words, no significant changes occurred in patients’ hearing threshold after surgery. No significant difference was also observed between horizontal and vertical movements in the results of tympanometry. Negative changes were found in the results of ETFT in vertical movements, which returned to pre-surgery values in the final test. @*Conclusions@#The risk of minor changes in hearing function is probable during the first week after orthognathic surgery, but these negative changes will either totally fade or remain negligible. Patients gave informed consent preoperatively, and reassurance postoperatively is prudent.

3.
Maxillofacial Plastic and Reconstructive Surgery ; : 15-2021.
Article in English | WPRIM | ID: wpr-918482

ABSTRACT

Background@#This study aimed to determine how successful reconstruction of the mandible can recover the symmetry. @*Materials and methods@#All patients who underwent surgical treatment for unilateral mandibular reconstruction in 4 years were retrospectively examined. Bilateral differences of gonion (GO) positions were measured in 3 dimensions based on immediate postoperative computed tomography. The data collected was analyzed in 3 ways: First, the comparison of bilateral differences of GO in 3 dimensions. Second, the mean Asymmetry Index in control subjects was used to divide all cases into three groups: “Symmetry,” “Asymmetry,” and “Marked asymmetry.” Third, “maximum normal asymmetry” was calculated, and all cases were categorized as below and above maximum normal asymmetry. The difference between two gonial angles was used to determine the amount of asymmetry. @*Results@#Forty-seven patients and 47 normal adults were enrolled. The mean bilateral GO difference in the control group was higher than in the study group patients, but it was not statistically significant. The mean Asymmetry Index for the control group was not also significantly higher than the study cases. The study group was “Symmetric” in 78.7% of the cases whereas the control group in 91.4%, 19.1% of the study group and 8.5% of controls were “Asymmetric,” and 2.1% of study cases and 0% of controls were “Markedly Asymmetric.” Maximum normal asymmetry was 82.9% in the study group and 97.8% in the control group. The mean differences between the right and left gonial angles were higher in the study group, but it was not significant (P = 0.1). @*Conclusions@#Our study’s results showed that bilateral symmetry in mandibular reconstruction patients was satisfactory and similar to the normal individuals.

4.
Restorative Dentistry & Endodontics ; : 229-235, 2015.
Article in English | WPRIM | ID: wpr-20254

ABSTRACT

OBJECTIVES: To determine and compare the fracture resistance of endodontically treated maxillary central incisors restored with different posts and cores. MATERIALS AND METHODS: Forty-eight upper central incisors were randomly divided into four groups: cast post and core (group 1), fiber-reinforced composite (FRC) post and composite core (group 2), composite post and core (group 3), and controls (group 4). Mesio-distal and bucco-lingual dimensions at 7 and 14 mm from the apex were compared to ensure standardization among the groups. Twelve teeth were prepared for crown restoration (group 4). Teeth in other groups were endodontically treated, decoronated at 14 mm from the apex, and prepared for posts and cores. Resin-based materials were used for cementation in groups 1 and 2. In group 3, composite was used directly to fill the post space and for core build-up. All samples were restored by standard metal crowns using glass ionomer cement, mounted at 135degrees vertical angle, subjected to thermomechanical aging, and then fractured using a universal testing machine. Kruskal-Wallis and Mann-Whitney U tests were used to analyze the data. RESULTS: Fracture resistance of the groups was as follows: Control (group 4) > cast post and core (group 1) > fiber post and composite core (group 2) > composite post and core (group 3). All samples in groups 2 and 3 fractured in restorable patterns, whereas most (58%) in group 1 were non-restorable. CONCLUSIONS: Within the limitations of this study, FRC posts showed acceptable fracture resistance with favorable fracture patterns for reconstruction of upper central incisors.


Subject(s)
Aging , Cementation , Crowns , Glass Ionomer Cements , Incisor , Tooth
5.
Journal of Dentistry-Shiraz University of Medical Sciences. 2015; 16 (Supp.): 50-55
in English | IMEMR | ID: emr-177131

ABSTRACT

Statement of the Problem: Vertical root fractures are catastrophic events that often result in tooth extraction. Many contributing factor are associated with increasing incidence of vertical root fracture. Root canal preparation is one of the predisposing factors which can increase the root susceptibility to vertical fracture


Purpose: The aim of this study was to compare the effects of three different instrumentation techniques on vertical root fracture resistance of endodontically treated teeth


Materials and Methods: In this study, 120 freshly extracted mandibular premolar teeth of similar dimensions were decoronated and randomly divided into control [n=30], nickel-titanium hand K-file [HF, n=30], BioRaCe rotary file [BR, n=30], and WaveOne reciprocating single-file [WO, n=30] groups. After cleaning and shaping the root canals, AH26 was used as canal sealer, and obturation was completed using the continuous wave technique. The root canals were embedded vertically in standardised autopolymerising acrylic resin blocks, and subjected to a vertical load to cause vertical root fracture. The forces required to induce fractures were measured using a universal testing machine. ANOVA and Tukey's post-hoc test were used to analyse the data


Results: All experimental groups showed statistically significant reductions in fracture resistance as compared with the control group. There was a statistically significant difference between the HF and BR groups. The WO group did not differ significantly from the HF group or the BR group


Conclusion: All three instrumentation techniques caused weakening of the structure of the roots, and rendered them susceptible to fracture under lesser load than unprepared roots. The fracture resistance of roots prepared with the single-file reciprocating technique was similar to that of those prepared with NiTi hand and rotary instrumentation techniques

6.
Restorative Dentistry & Endodontics ; : 222-226, 2013.
Article in English | WPRIM | ID: wpr-157856

ABSTRACT

OBJECTIVES: The aim of this study was to assess the influence of operator experience level on the lifespan of the WaveOne Primary file (Dentsply Maillefer, Ballaigues, Switzerland) in extracted teeth. MATERIALS AND METHODS: Moderately curved canals of extracted maxillary and mandibular molars were randomly distributed into 2 groups: experienced and inexperienced operators. Ten files were allocated to each group (n = 10). Each canal was prepared until the working length was reached, and the same file was used to prepare additional canals until it separated. The number of canals prepared before file separation was recorded. The fragment length of each file was measured, and the location of the fragment in the canal was determined. Data were statistically analysed using the independent 2-sample t-test. RESULTS: The 2 operators prepared a total of 324 moderately curved canals of maxillary and mandibular molars. There was no significant intergroup difference in the mean number of canals prepared (p = 0.27). The average lifespan of the WaveOne Primary file was 17.1 and 15.3 canals, and the longest lifespan was 25 and 20 canals, when used by experienced and inexperienced operators, respectively. There were no statistically significant intergroup differences in separated fragment length and location. CONCLUSIONS: Within the limitations of this study, operator experience level appears to have no effect on the lifespan of the WaveOne Primary file in preparation of moderately curved canals. Single teeth with multiple canals can be prepared safely even by a novice operator by using a single file.


Subject(s)
Molar , Tooth
SELECTION OF CITATIONS
SEARCH DETAIL